- Basic Accuracy: 0.015% (Source & Measure)
- 20 mA SIMULATE (SINK) function
- Simultaneously supplies 24V loop power and measures output signal with high accuracy
- HART/BRAIN comm. resistance (250Ω) embedded
- Sub-display displays span% of the source value
- Corresponds to various types of the source pattern
(Step sweep/ Linear sweep/ Manual step/ Span check)
Yokogawa CA300 Series Process Calibrator
Yokogawa CA310 Volt Current Loop Calibrator
The Yokogawa CA310 is a top-of-the-line Volt mA calibrator that belongs to the CA300 series. As a high-accuracy source, the CA300 series process calibrator is perfect for inspecting and maintaining the accuracy of various control devices used in process plants, industry machinery, and manufacturing, such as temperature controllers, temperature transmitters, temperature sensors, and other process devices.
The CA310 Volt mA calibrator is equipped with a voltage and current simulate model that enables it to execute a loop check by simulating a transmitter and sinking the current signal from an external source. It boasts an impressive accuracy of 0.015% of setting to source 4mA to 20mA, making it one of the most reliable calibrators in the market.
Furthermore, the CA310 is also capable of measuring DC mA signals by supplying power to the transmitter from a 24V DC power supply, and it can perform zero-point check and DC mA measurement with a high accuracy of 0.015% of reading.
To make things even more convenient, the Yokogawa CA310 comes with a 250-ohm resistor for HART and BRAIN communication, eliminating the need to attach an external resistor when connecting to a handy terminal. If you’re looking for a top-performing Volt mA calibrator, the Yokogawa CA310 is definitely a product you shouldn’t miss.
20mA SIMULATE
CA310 can execute a loop check by simulating a transmitter, sinking the current signal from the external source (distributor). It achieves a high accuracy of015% of setting to source 4-20mA.
Two-wire Transmitter Loop Check
DC mA signals can be measured by supplying power to the transmitter from a 24 V DC power supply. DC mA measurement and zero-point check can be performed with an accuracy of 0.015% of reading. A 250-ohm resistor for HART and BRAIN communication is included in this calibrator, o there is no need to attach an external resistor when connecting to a handy terminal.
Addition of Sub Display
The sub-display additionally shows span%, source value of voltage, or resistance, while the main display shows the setting value.