Presicion Digital PD6801 ProtEX-F&I Loop-Powered Level Meter

The Precision Digital ProtEX-F&I PD6801 is one of Precision Digital’s most advanced and feature-packed explosion-proof, loop-powered indicators explicitly designed for level applications that require a feet & inches display. The PD6801 can indicate up to 699 feet, 11 and 15/16 (or 7/8) inches. Like all ProtEX products, the PD6801 explosion-proof level indicator carries FM, CSA, ATEX, and IECEx approvals for use in hazardous areas. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. Two features that make the PD6801 stand out are its wide viewing angle display and SafeTouch® through-glass buttons. These buttons allow the PD6801 tank-side indicator to be programmed and operated through the glass, eliminating the need to remove the cover in a hazardous area.

  • Display Level in Feet & Inches
  • 4-20 mA Input Loop-Powered
  • Programmable 1/8 or 1/16 Inch Display
  • 20-Segment Tank Level Indicator
  • Lower Display for Tag, Volume, or Percent
  • SafeTouch® Through-Glass Button Programming
  • Open Collector Alarm Output
  • Loop-Powered or External DC-Powered Backlight Standard
  • Explosion-Proof, IP68, NEMA 4X Enclosure
  • Operates from -40 to 75°C

General

Display: Feet & Inches display: 0.60″ (15.2 mm) high, 0 to 699 FT – 11 15/16 IN with 1/16 or 1/8 fraction display.
Lower 7-digit display: 0.4″ (10.2 mm) high, 14-segment alphanumeric characters, display tag, volume 0 to 9999999, and/or 0-100 percent.
Tank Level Indicator: 20 segments, F (Full) and E (Empty)
Alarm Indication: HI and LO; Backlight: White, loop or DC powered
Display Assignment: Lower display may be assigned to custom unit or tag, volume, volume and tag, percent height, percent height and tag, or off.
Display Update Rate: Ambient > -25°C: 2 Updates/Second Ambient < -25°C: 1 Update/5 Seconds
Externally Powered Backlight:
Voltage Range: 9-36 VDC

Supply Voltage9 VDC12 VDC24 VDC30 VDC
Maximum Power0.2 W0.25 W0.5 W0.75 W

Overrange and Underrange: Level display flashes to 699 FT 11 15/16 IN Volume display flashes 9999999 if overrange, -999999 if underrange.
Programming Method: Four SafeTouch through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
Noise Filter: Programmable low (LO), medium (MED), high (HI), or off (OFF)
Recalibration: Recalibration is recommended at least every 12 months.
Password: Programmable password restricts modification of settings.
Nonvolatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Normal Mode Rejection: 64 dB at 50/60 Hz
Environmental: Operating temperature range: -40 to 75°C
Storage temperature range: -40 to 75°C
Relative humidity: 0 to 90% non-condensing
Connections: Screw terminals accept 12 to 22 AWG wire
Enclosure: Explosion-proof die cast aluminum with glass window, corrosion resistant epoxy coating, color: blue. NEMA 4X IP68. Two ¾” NPT threaded conduit openings. One ¾” NPT metal conduit plug with 12 mm hex key fitting installed.
Mounting: May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½” to 2½” or DN 40 to 65 mm pipe mounting. 
Overall Dimensions: 5.65″ x 5.25″ x 4.86″ (W x H x D) (144 mm x 133 mm x 124 mm)
Weight: 5.00 lbs (80 oz, 2.27 kg)
Warranty: 3 years parts and labor

Input

Accuracy: ±0.03% of calibrated span ±1 count
Input Range: 3 to 24 mA
Multi-Point Linearization: 2 to 32 points each for level and volume
Temperature Drift: 50 PPM/°C from -40 to 75 °C ambient
Calibration Range:
Input Range: 4-20 mA, Input 1 & 2 Minimum Span: 0.10 mA
Maximum Voltage Drop: Without Backlight or with Externally-Powered
(DC Powered) Backlight: 3.0 VDC @ 20 mA
With Loop-Powered Backlight: 6.0 VDC @ 20 mA
Equivalent Resistance: 150 Ω @ 20 mA without loop-powered backlight. 300 Ω @ 20 mA with loop-powered backlight.
Input Overload: Over current protection to 2 A max.
HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal

Open Collector Output

Alarm Output: Assign to level or volume for high or low alarm trip point.
Deadband: 0-100% FS, user selectable
Acknowledge: Front panel ENTER button and external RESET terminals resets output and screen indication.

Product Ratings & Approvals

FM: Explosion-proof for use in Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III, Division 1; T6
Class I, Zone 1, AEx d IIC T6 Gb
Zone 21, AEx tb IIIC T85°C
Ta = -40 to 75°C
Enclosure: Type 4X & IP66
Certificate number: 3040391
ATEX: II 2 G D Ex d IIC T6 Gb
Ex tb IIIC T85°C Db IP68
Ta = -40 to 75°C
Certificate number: Sira 10ATEX1116X
CSA: Class I, Division 1, Groups B, C, D Class II, Division 1, Groups E, F, G
Class III, Division 1; T6
Class I, Zone 1, Ex d IIC T6
Ta = -40 to 75°C. Enclosure: Type 4X & IP66
Certificate number: 11 2325749
IECEx: Ex d IIC T6 Gb Ex tb IIIC T85°C Db IP68
Ta = -40 to 75°C
Certificate number: IECEx SIR 10.0056X

Connections

 
 
 

Dimensions

Data Sheet: LDS6801 Data Sheet
Instruction Manual: LIM6801_0 Instruction Manuals

Shopping Cart