The Vantageview PD6701 is one of Precision Digital’s most advanced and feature-packed plastic, field-mounted, loop-powered indicators designed specifically for level applications that require a feet & inches display. The PD6701 can indicate up to 399 feet, 11 and 15/16 (or 7/8) inches. The PD6701 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. Two features that really make the PD6701 stand out are its wide viewing angle display and SafeTouch® through-window buttons. These buttons allow the PD6701 tank-side indicator to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.
Precision Digital PD6701 Loop-Powered Level Meter
- 4-20 mA Input
- Modern, Sleek and Practical Enclosure for Safe Areas
- 3½ Digits, 1″ (25.4 mm) Display
- Display Mountable at 0, 90, 180, & 270 Degrees.
- Easy Calibration and Installation
- Loop-Powered Backlight Option
- 1 V Drop (4 V with Backlight)
- Plastic NEMA 4X, IP65 Enclosure
- Flanges for Wall or Pipe Mounting
- HART Protocol Transparent
- Operates from -40 to 75°C
General
Display: 3½ digit LCD, 1″ (25.4 mm); -1,999 to 1,999
Display Update Rate: 2.5 Updates/Second
Display Orientation: Display may be mounted at 90° increments up to 270° from default orientation
Overrange: Display reads 1 on the left most digit
Programming Method: Four front mounted rotary control dials accessed when the cover is removed.
Recalibration: Recommended at least every 12 months.
Normal Mode Rejection: 60 dB rejection ratio
Operating Temperature Range: -40 to 75°C
Storage Temperature Range: -40 to 75°C
Relative Humidity: 0 to 90% non-condensing
Connections: Screw terminals accept 12 to 22 AWG wire
Enclosure: NEMA 4X, IP65 plastic field enclosure. Color: grey. Material: Polycarbonate with UV Stabilizer. Three ¾” NPT threaded conduit Two ¾” NPT plastic conduit plugs, with 1.29″ wrenching flats and a screwdriver slot, are included.
Mounting: May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½” to 2½” or DN 40 to 65 mm pipe mounting.
Overall Dimensions: 5.67″ x 5.25″ x 4.18″ (144 mm x 133 mm x 106 mm) (W x H x D)
Weight: 1.65 lbs (26.4 oz, .75 kg)
Warranty: 3 years parts and labor
Input
Input: 4-20 mA
Accuracy: ±0.1% of full span ±1 count
Temperature Drift: 150 PPM/°C from -40 to 75°C ambient
Decimal Point: User selectable decimal point
Calibration Range: 4 mA input: -1000 to +1000; 20 mA between 20 and 2000 counts greater than 4 mA display. Two point linear display span.
Maximum Voltage Drop: 1 VDC @ 20 mA without backlight; 4 VDC @ 20 mA with loop-powered backlight.
Input Overload: Over current protection to 2 A max.
HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal
Loop-Powered Backlight Option: Factory installed only. Powered directly from the 4-20 mA loop, no batteries required. Backlight can be enabled or disabled via alternative wiring of terminal block. The display brightness will increase as the input signal current increases.
Data Sheet: Predig PD6701 Datasheets
Instruction Manual: Predig PD6701 Instruction manual