OWON HDS-N Series 1-Channel Digital Oscilloscope

OWON HDS2061M-N

SKU: HDS2061M-N Category:

Email Us: sales@mycelectric.com
WhatsApp Us: +6016-551 9084
WhatsApp Channel: Follow Our WhatsApp Channel

  • 2 in 1 (DSO + Multimeter)
  •  Auto-scale function
  • 20 automatic measurements
  • Bandwidth : 20MHz – 100MHz
  • USB data transmission supported
  • Waveform record and replay
  • Multimeter newly supported SCPI
  • Rechargeable Li-ion battery (6 hours’ backup)
  1. 2-in-1 station

Oscilloscope + 3 3/4 digits multimeter + FFT spectrum analyzer.

Oscilloscope + Multimeter

  1. Auto-scale Function

While in auto-scale status, the oscilloscope will switch to the specific trigger mode, vertical scale, and timebase scale according to the type, amplitude and frequency of input signal.

Auto-scale Function

  1. Trigger Sensitivity Adjustable

Original adjustable trigger sensitivity, greatly filter the overlay noise and trigger the signal stably under noise circumstance.

Trigger Sensitivity Adjustable

skuHDS2061M-N
 Bandwidth 60MHz
 Sample Rate (real time ) 500MS/s
 Horizontal Scale (s/div) 5ns/div~100s/div, step by 1~2.5~5
 Display 3.7” color TFT display (640 × 480 pixels)
 Channel single
 Record Length 24K points
 Vertical Sensitivity 5mV/div~5V/div (at input)
 Vertical Resolution (A/D) 8 bits
 Trigger Type Edge, Video and Alternate
 Trigger Mode Auto, Normal, and Single
 Trigger Level ±6 divisions from screen center
 Acquisition Mode Sample, Peak Detect, and Average
 Waveform Storage 4 waveforms
 Communication Interface mini-USB,mini-RS232
 Power Supply 100V-240V AC, 50/60Hz
 Li-ion Battery 7.4V, 6 hours’ operation
 Dimensions (W × H × D) 115 × 180 × 40 (mm)
 Weight (without package) 645.00 g
Multimeter Specifications
Full Scale Reading 3(3/4)digits (max 4000-count) diode 0V-1.5V
Input Impedance 10 MΩ On / Off Test < 50 (± 30) beeping
VoltageVDC : 400mV, 4V, 40V, 400V, 1000V : ±(1% ± 1 digit); max input : DC 1000V 
VAC : 4V, 40V, 400V : ±(1% ± 3 digits), 750V : ±(2% ± 3 digits); Frequency : 40Hz – 400Hz; 
max input : AC 750V (virtual value)
CurrentDC : 40mA, 400mA : ±(1.5% ± 1 digit), 10A : ±(3% ± 3 digits) 
AC : 40mA : ±(1.5% ± 3 digits), 400mA : ±(2% ± 1 digit), 10A : ±(5% ± 3 digits)
Impedance 400Ω : ±(1% ± 3 digits), 40ΚΩ – 4ΜΩ : ±(1% ± 1 digit), 40MΩ : ±(1.5% ± 3 digits)
Capacitance 51.2nF – 100uF : ±(3% ± 3 digits)

Data Sheet:
Instruction Manual: