The Series DPG-200 Digital Pressure Gage has a precise ±0.25% full scale accuracy. The 4 digit digital display will reduce the potential for errors in readings by eliminating parallax error commonly produced with analog gages. The DPG-200 is packaged in a durable extruded aluminum case designed to meet NEMA 4X (IP66). The unit is powered by 12-24 VDC/VAC and contains two alarm set points along with a 4-20 mA process output. A four-button keypad allows easy access to features. These features include backlight, peak and valley, auto zero and conversion of the pressure units.
Product Applications
- Level Control
- Pump Control
- Process Control
- Compressor Control
DIGITAL GAGE SPECIFICATIONS
Service : Liquids and non-combustible compatible gases.
Wetted Materials : Type 316L SS.
Housing : Black polycarbonate front & back cover, anodized aluminum extruded housing with recessed grooves, polycarbonate overlay, Buna-N O-rings, 316L SS sensor construction.
Accuracy : 0.25% F.S. ±1 least significant digit. (Includes linearity, hysteresis, repeatability).
Pressure Limit : 2x pressure range for skus 1000 psi; 5000 psi for 3000 psi range; 7500 psi for 5000 psi range.
Temperature Limits : 32 to 158°F (0 to 70°C).
Process Connection:1/4″ male NPT.
Display : 4 digit (.425″ H x .234″ W digits).
Size : 3.00″ OD x 1.90″ deep (not including cables).
Weight : 8.84 oz (275 g).
SWITCH SPECIFICATIONS
Switch Type : 2 SPDT Form C contacts.
Electrical Rating : 0.5 A @ 125 VAC resistive, 1 A @ 24 VDC.
Relay Differential : 1 least significant digit.
Electrical Connections : 3 ft (.91 m) cable.
Mounting Orientation : Mount in any position.
Set Point Adjustment : Via menu.
TRANSMITTER SPECIFICATIONS
Temperature Limits : 0 to 158°F (0 to 70°C).
Thermal Effect : Between 70 to 158°F = 0.016%/°F. Between 0 to 70°F = 0.026%/°F.
Power Requirements : 12-24 VAC +/- 20% 50-400 Hz, 12-24 VDC +/-20%.
Output Signal : 4-20 mA.
Loop Resistance : 600 ohms maximum.
Power Consumption : 0.8 W max.
Electrical Connections : 3 ft (.91 m) cable.
Enclosure Rating : Designed to meet NEMA 4X (IP66).