Yokogawa RotaMASS Hygienic Flow Meter

With pure dedication
Specifically designed and certified for food & beverage, biotechnology and pharmaceutical utility applications. (EHEDG certified, 3-A certified)
This series is the appropriate answer to the daily constraints of hygienic processes ensuring continuous product quality and minimizing losses. This is made easy by the provided multi-variable measurement and various dedicated features.

Typical Applications

  • Bioreactor feeds
  • Bottling
  • Carbonation of beverages
  • Deionized water
  • Fermentation
  • Juice processing
  • Molasses measurement
  • Online sugar concentration
  • Raw milk tanker unloading
  • Process water reclamation
  • Product quality control
  • Sugar industry

Sensors

Product LineROTAMASS
Nano
ROTAMASS
Prime
ROTAMASS
Hygienic
ROTAMASS
Supreme
ROTAMASS
Intense
ROTAMASS
Giga
Liquid process fluids
Liquids in general
Aggressive liquids
High viscous fluids
Gaseous process fluids
Gases in general
Low density gases
Mixed process fluids
Unmixable or mixable liquids
Liquids with entrained gas
Process conditions
Process temperature-50 to +260 °C
-58 to +500 °F
-70 to +200 °C
-94 to +392 °F
-70 to +140 °C
-94 to +284 °F
-196 to +350 °C
-321 to +662 °F
-70 to +150 °C
-94 to +302 °F
-70 to +350 °C
-94 to +662 °F
Process pressure up to285 bar or
460 bar *1
4183 psi or
6672 psi *1
100 bar
1450 psi
40 bar
580 psi
100 bar or
250 bar *1
1450 psi or
3626 psi *1
260 bar or
360 bar *1
3771 psi or
5221 psi *1
100 bar or
180 bar *1
1450 psi or
2610 psi *1
Line sizesDN15 to DN40
1/4 in. to 1 1/2 in.
DN15 to DN125
3/8 in. to 5 in.
DN25 to DN80
1 in. to 3 in.
DN15 to DN125
3/8 in. to 5 in.

3/8 in. to 2 in.
DN100 to DN200
4 in. to 8 in.
Accuracy
Mass flow for liquids up to± 0.1 %± 0.1 %± 0.1 %± 0.1 %± 0.1 %± 0.1 %
Mass flow for gas up to± 0.35 %± 0.35 %± 0.35 %± 0.35 %± 0.35 %± 0.35 %
Density for liquids up to± 0.5 g/l± 0.5 g/l± 0.5 g/l± 0.5 g/l± 0.5 g/l± 1.0 g/l
Turndown flat accuracy
Materials and process connections
Material of wetted partsAlloy C-22/2.4602 & 316L/1.4404316L/1.4404316L/1.4404316L/1.4404 or alloy C-22/2.4602 or 304/1.4301 *1316L/1.4404 or alloy C-22/2.4602 or 304/1.4301*1316L/1.4404 or alloy C-22/2.4602
Flange process connectionsEN, ASME, JPI, JISEN, ASME, JPI, JISEN, ASME, JPI, JISASMEEN, ASME, JIS
Threaded process connectionsG, NPTG, NPTDIN11851, SMS1145G, NPTG, NPT
Clamp process connectionsDIN32676DIN32676, JIS/ISO2852DIN32676, JIS/ISO2852
Sensor design
Insulation and heat tracing options
Rupture disk○ *1
Customer & NAMUR face-to-face length
Approvals / Certificates
3-A or EHEDG application
Marine application
Functional SafetySIL 2 (SIL3)
Hazardous area approvalsIECEx, ATEX, FM (USA/Canada), NEPSI, INMETRO, PESO, EAC Ex, Taiwan Safety Label, Korea Ex, Japan Ex, ECAS Ex, Ukraine Ex

●: supported    ○: supported under certain conditions    -: not supported    *1: available on demand

General Specification: Yokogawa RotaMASS Hygienic Flow Meter spec

Manual: Yokogawa RotaMASS Hygienic Flow Meter manual