Last Updated: 16/04/2020
Yokogawa Logo

Yokogawa CA500 Series Multi-Function Process Calibrator

Request a Quote
close-link

Part Number: CA500/CA550 Categories: ,
  • Free Shipping
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email [email protected]

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
  • Free Technical Support
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
  • Multi-function

    • Sources and measures DC voltage, DC current, RTD, TC, resistance, frequency and pulse signals
    • Corresponds to 17 types of TC standard (JIS/IEC/DIN/ASTM/GOST R)
    • Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)

    Multiple source patterns

    Linear sweep function
    Continuously Source from 0% to 100%

    Step sweep function
    Change output in a staircase (step) pattern by specifying the number of steps. (The number of steps can be set from 2 to 20)

    Program sweep function
    Users can set the desired output value (%) and the number of steps. (10 steps for CA500, 20 steps for CA550)

    Design

     

    The Yokogawa CA500 series are high-performance, multi-function calibrators designed for use in multiple applications. Featuring useful functions for fieldwork, these multi-function calibrators help you calibrate field instruments with improved source and measurement accuracy. 

    Two models are available, offering two different levels of accuracy:

    • The CA550 achieves an accuracy of 0.010% (DC current), 0.015% (resistance), and 0.1˚C (RTD).
    • The CA500 achieves an accuracy of 0.015% (DC current), 0.020% (resistance), and 0.3˚C (RTD). 

    Functions

    Automatic input/output testing *CA550 only
    (Program sweep)

    Automatic input/output testing is possible by setting source values for each step for a calibration target. Calibration results such as generated value, measured value, error rate, date/time, and pass/fail are saved in CSV format in the CA550 main unit.

    By connecting the CA550 to a PC using a standard USB cable, the instrument can be recognized as a mass-storage device for data to be transferred to the PC.

    HART Communication Protocol *CA550 only

    The following items are supported by HART communication function:

    • TagNo.
    • PV value (including reading of PV %value, AO value, SV value, TV value, QV value)

    Read

    • LRV (Lower limit of range)
    • URV (Upper limit of range)
    • Damping

    Read and Write

    • Trimming of 4 mA
    • Trimming of 20 mA

    Write

    *Please note that not all commands are supported by HART communication.
    *TagNo acquisition function is available in BRAIN communication. No other functions are available.

    Easy-to-view Display

    CA500 features a Reflective LCD, providing improved outdoor visibility. Main display (generated/measured values) and Sub display (%, mV, Ω, etc.) allow required information at a work site to be confirmed at a glance.

    CA500 Dual LIne Display

    Wiring information display function

    A wiring diagram is displayed according to the function selected. This function allows a user to perform wiring while referring to a wiring diagram and prevents miss wiring.

    CA500 Wiring Diagram

    Thermocouple generation using TC Mini Plug

    Using a TC Mini Plug together with a compensating lead wire enables the generation of thermal electromotive force without an external RJ sensor.*
    * A compensating lead wire needs to be prepared by customer.

    CA500 Thermocouple Connector

    Easy-to-use key operation

    0%/100% keys
    The source can be easily switched between 0% and 100% of range. Users can also set the desired value.

    UP/DOWN keys
    The output is changed in preset steps by pressing UP or DOWN key.

     

    Operation key layout
    Keys related to generation and measurement are arranged collectively to allow easy and intuitive operation.

    SQUARE ROOT output

    For 4-20 mA, 1-5 V ranges, users can choose between LINEAR and SQUARE ROOT output.

    4 to 20 mA SIMULATE

    The Yokogawa CA500 series can be used as a transmitter simulator to perform a loop test. It sinks the set current from an external voltage source of instrumentation equipment.

    Two-wire Transmitter Loop Check

    DC mA signals can be measured by supplying power to the transmitter from a 24 V DC power supply. DC mA signal measurement and zero-point check can be performed with an accuracy of 0.01% of reading (0.015% of reading for CA500).

    Calibrate Signal DistributorCalibrate 2-Wire Transmitter

    Zero-point adjustment of HART transmitter

    CA550 supports HART communication (Universal command/Common practice command).
    Reading of HART device information, writing of LRV/URV, and trimming of analogue output are possible.

    TC SIMULATE

    The CA500 series corresponds to 17 types of TC for sourcing. It achieves the high basic accuracy of 0.5°C (typical of type K), two times better than the previous model.
    Also, input/output testing is possible with a single CA500/CA550, as it can measure output signals.

    Zero Point Adjustment TransmitterCalibrate Controller

    RTD SIMULATE

    CA500/CA550 corresponds to 14 types of RTD for sourcing. It achieves a high basic accuracy of 0.1°C* (typical of type Pt100), which enables it to operate a highly reliable test.
    Additionally, input and output testing of temperature transmitters are possible at the same time.
    *Accuracy for CA550

    Pulse SIMULATE

    This calibrator measures pulse signal integration from a flowmeter and generates a pulse to a receiver, such as integrating counter or pulse converter. Integration time can be set from 1 min to 60 min.

    Calibrate Temperature TransmitterPulse Simulation

    Data Sheet: Yokogawa CA500 Series Brochure
    User Manual: Yokogawa CA500 Series User Manual

    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email [email protected]

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
    close-link

    Product of the week

    Loop Powered Indicator
    Loop Powered Flow Indicating Totalizer are in-stock now, and deliver immediately.
    Free delivery within Malaysia.
    Buy Here!
    close-link
    Scroll to Top
    ×