Precision Digital PD6200 ProVu Analog Input Flow Rate Totalizer

Last Updated: 28/03/2020
Precision Digital Logo

Precision Digital PD6200-6H0

$592

Usually ships in 1 to 2 weeks

Part Number: PD6200-6H0 Categories: , Tags: , ,
  • Free Shipping
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email [email protected]

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
  • Free Technical Support
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
  • Request a Quote
    close-link

    SKU: PD6200-6H0 
    Product Type: 1/8 DIN Flow Rate/Totalizer Digital Panel Meter 
    Input: Current (4-20 mA), Voltage (0-10 V) 
    Output Options: None 
    Power: 85-265 VAC, 90-265 VDC 
    Approvals: CE, UL/C-UL 
    Transmitter Power: 24 VDC @ 200 mA 
    Display Category: LED, Dual Line, Sunlight Readable 
    Display: SunBright, 0.6″, Dual Line, 6 Digits, Red LED 
    Warranty: 3 years 
    Product Series: ProVu 
    Product Family: PD6200 
    Product category: Digital Panel Meters 
    Product Application: Flow Rate Totalizer

    Wiring Diagram:

    The Precision Digital PD6200 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and totalizer from an analog output (4-20 mA, 1-5 V, 0-5 V, etc.) flowmeter. It displays that signal on a dual-line, 6-digit display that is available with optional Sunbright® sunlight-readable LEDs. Flow rate is typically displayed on the upper line, and the cumulative total is displayed on the lower line. The total overflow feature allows up to a 9-digit total and grand total to be displayed. Like all ProVu meters, the PD6200 includes CE Marking and UL / C-UL listing, a NEMA 4X front, and AC or DC power options. Precision Digital ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6200 includes a 24 VDC transmitter power to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    General

    Display: Upper display: 0.60″ (15 mm) high. Lower display: 0.46″ (12 mm) high. Both are 6 digits (-99999 to 999999), red LEDs.
    Display Intensity: Eight user selectable intensity levels
    Display Update Rate: 5/second (200 ms)
    Overrange: Display flashes 999999
    Underrange: Display flashes -99999
    Display Assignment: The upper and lower displays may be assigned to rate, total, grand total, alternate (rate/total, rate/grand total, rate/units, total/units, and grand total/units), max/min, units (lower display only), set points, or Modbus input. Additional displays are available if parameter total is off, abd parameter d-SCAL is on: gross, alternating gross/net, PV1, PV2, and PCT (refer to PD6000 instruction manual).
    Front Panel: NEMA 4X, IP65
    Programming Methods: Four front panel buttons, digital inputs, PC and MeterView Pro software, Modbus registers
    F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
    F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC
    Logic Low: 0 to 1.25 VDC
    Noise Filter: Programmable from 2 to 199 (0 will disable filter)
    Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
    Recalibration: All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
    Max/Min Display: Max (Peak) / min (Valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled.
    Password: Three programmable passwords restrict modification of programmed settings and two prevent resetting the totals.
    Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
    Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
    Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse.
    Isolated Transmitter Power Supply:Terminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
    Normal Rejection Mode: Greater than 60 dB at 50/60 Hz
    Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply.
    Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
    Environmental:
    Operating temperature range: -40 to 65°C
    Storage temperature range: -40 to 85°C
    Relative humidity: 0 to 90% non-condensing
    Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters.
    Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
    Mounting: 1/8 DIN panel cutout required: 3.622″ x 1.772″ (92 mm x 45 mm). Two panel mounting bracket assemblies are provided.
    Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
    Dimensions: 4.68″ x 2.45″ x 5.64″ (119 mm x 62 mm x 143 mm) (W x H x D)
    Weight: 9.5 oz (269 g)
    UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment.
    Warranty: 3 years parts & labor USB Connection: Compatibility: USB 2.0 Standard, Compliant
       Connector Type: Micro-B receptacle
       Cable: USB A Male to Micro-B Cable
       Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
       Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
       Power: USB Port

    PD6200 Analog Inputs

    Inputs: Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (Slave)
    Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span
    Temperature Drift: 0.005% of calibrated span/°C max from 0 to 65°C ambient, 0.01% of calibrated span/°C max from -40 to 0°C ambient
    Math Function: Linear, square root, programmable exponent, or round horizontal tank volume calculation.
    Multi-Point Linearization: 2 to 32 points
    Programmable Exponent: 1.0001 to 2.9999
    Low-Flow Cutoff: 0-999999 (0 disables cutoff function)
    Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd.
    Calibration Range:

    Input RangeMinimum Span Input 1 & 2
    4-20 mA0.15 mA
    ±10 V0.10 V

    An Error message will appear if input 1 and input 2 signals are too close together.
    Input Impedance: Voltage ranges: greater than 500 kΩ. Current ranges: 50 – 100 Ω (depending on resettable fuse impedance).
    Input Overload: Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed.
    HART Transparency: Analog input will not interfere with existing HART communications on the wired 4-20 mA signal

    Relays

    Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (≈ 50 W) @125/250 VAC for inductive loads
    Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads.
    Relay Assignment: Relays may be assigned to rate, total, or grand total.
    Deadband: 0-100% of span, user programmable
    High or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turned off).
    Relay Operation: automatic (non-latching), latching (requires manual acknowledge), sampling (based on time), pump alternation control (2 to 8 relays), off (disable unused relays), and manual on/off control mode.
    Relay Reset: User selectable via front panel buttons, digital inputs, or PC
       1. Automatic reset only (non-latching), when input passes the reset point or total is reset to zero.
       2. Automatic + manual reset at any time (non-latching).
       3. Manual reset only, at any time (latching).
       4. Manual reset only after alarm condition has cleared (latching).
        Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset.
    Time Delay: 0 to 999.9 seconds, on & off relay time delays. Programmable and independent for each relay.
    Fail-Safe Operation: Programmable and independent for each relay.
    Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state.
    Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.

    Isolated 4-20 mA Transmitter Output

    Output Source: Rate/process, total, grand total, max, min, set points 1-8, manual control setting, or Modbus input
    Scaling Range: 1.000 to 23.000 mA for any display range
    Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
    Analog Output Programming: 23.000 mA maximum for all parameters: Overrange, underrange, max, min, and break
    Accuracy: ±0.1% FS ±0.004 mA
    Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
    Note: Analog output drift is separate from input drift.
    Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10%. Isolated from the input at >500 V. May be used to power the 4-20 mA output or other devices. All models rated @ 40 mA max.
    External Loop Power Supply: 35 VDC maximum
    Output Loop Resistance:

    Power supplyMinimumMaximum
    24 VDC10Ω700Ω
    35 VDC (external)100Ω1200Ω

    Serial Communications

    Protocol: Modbus® RTU
    Meter Address/Slave ID: 1 – 247
    Baud Rate: 300 – 19,200 bps
    Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication
    Data: 8 bit (1 start bit, 1 or 2 stop bits)
    Parity: Even, odd, or none with 1 or 2 stop bits
    Byte-to-Byte Timeout: 0.01 – 2.54 second
    Turn Around Delay: Less than 2 ms (fixed)
    Note: Refer to the ProVu Modbus Register Tables for details

    Digital I/O Expansion Module

    Channels: 4 digital inputs & 4 digital outputs per module
    System: Up to 2 modules for a total of 8 inputs & 8 outputs
    Digital Input Logic: High: 3 to 5 VDC Low: 0 to 1.25 VDC
    Digital Output Logic: High: 3.1 to 3.3 VDC Low: 0 to 0.4 VDC
    Source Current: 10 mA maximum
    Sink Current: 1.5 mA minimum
    +5 V Terminal: To be used as pull-up for digital inputs only

    4-Relay Expansion Module

    Relays: Four Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (approx. 50 watts) @ 125/250 VAC for inductive loads.

    Applications

    Differential Pressure Flow

    The PD6200 can display flow rate and total by extracting the square root from the 4-20 mA signal from a differential pressure transmitter. The user selectable low-flow cutoff feature gives a reading of zero when the flow rate drops below a user selectable value.

    • Display Flow Rate
    • User Selectable Low-Flow Cutoff
    • Only 2 Calibration Points Required

    Convert Pulse to 4-20 mA with PD6300

    The PD6300 accepts the pulse output from a flowmeter and with the appropriate option installed can convert the pulse to a 4-20 mA signal. The 4-20 mA signal can be programmed to correspond to either the flow rate or the total flow.

    • Use K-Factor or Multi-Point Scaling
    • ProVu Powers the Flowmeter
    • Display Flow Rate & Total

    Open Channel Flow

    The PD6200, in combination with an ultrasonic level transmitter, makes for an economical way to measure and display open channel flow rate and total in most weirs and flumes and take periodic samples. All the user needs to do is enter the exponent for the weir or flume into the PD6200 and the PD6200 automatically raises the input signal to that power. Sampling can be based on the total flow or the flow rate. For instance, to display open channel flow rate and total from a 3 inch Parshall flume and take a one pint sample every 100,000 gallons, the user would program the PD6200 as follows:

    FunctionDesireProgramming
    Open Channel Flow3″ Parshall flumeSet Programmable Exponent to 1.547
    Flow RateMillions of Gallons per Day (MGD)Set 4 mA = 0 & 20 mA = 3.508
    Time base = Day
    TotalMillions of GallonsSet Totalizer Conversion Factor = 1
    (password protect total reset)
    Non-Resettable Grand TotalProgram meter so grand total can never be resetSet non-resettable grand total password
    DisplayDisplay Flow Rate and Total at the same timeSet main display for Grand Total and secondary display to toggle between rate and total
    SamplingTake a 1 pint sample every 100,000 gallonsSet up relay for sampling and to trip every 0.1 million gallons. Set up sampling time such that 1 pint is sampled
    Relay Sample Total
    Total Relay Sampling Operation

    Connections

    PD6200 Connections

    PD6300 Connections

    Mounting Dimensions

    ProVuDimensions


    Notes:

    1. Panel cutout required: 1.772″ x 3.622″ (45mm x 92mm)
    2. Panel thickness: 0.040 – 0.250″ (1.0mm – 6.4mm)
    3. Mounting brackets lock in place for easy mounting
    4. Clearance: Allow 6″ (152 mm) behind the panel

    MeterView® Pro Software

    MeterView® Pro software is designed for use with ProVu, ProtEX-MAX, or Helios Series meters and allows users to remotely program, monitor, and datalog using a PC. Remote programming allows for all available meter settings to be programmed through an easy, user-friendly interface. The data acquisition feature allows the user to gather readings from a meter at user-selected intervals and generate charts using common tools like Microsoft® Excel. A linearization setup function is also included. With this utility the user can configure up to 32 linearization points and upload them to the meter. All configuration data can be saved to a file for future use.
    This software is accessible via the onboard USB connection on all Helios large display meters, ProVu panel meters, and ProVu-based ProtEX-MAX explosion-proof meters produced since 6 September 2016 (firmware version 4.0 or higher). In order for meters produced prior to 6 September 2016 (firmware version 3.1 or lower) to establish digital communications with a PC, a serial communications adapter is required. For an RS-232 connection, use a PDA1232 adapter.
    To determine the software version of a meter:

    1. Go to the Diagnostics menu () and press Enter button.
    2. Press Up arrow button and scroll to Information menu (Info).
    3. Press Enter to access the software number (), version (), and serial number () information. Write down the information as it is displayed. Continue pressing Enter until all the information is displayed.
    4. The meter returns to Run Mode after displaying all the settings.

    Monitor and Datalog

    Monitor and Datalog

    Setup

    Setup

    Programming

    Programming

    Relays

    Relays

    Data Sheet:LDS6200 Datasheets

    Instruction Manual:  LIM6200_1 Instruction Manuals

     

    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email [email protected]

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
    close-link
    Scroll to Top
    ×