Precision Digital PD2-6300 Helios Pulse Input Flow Rate Totalizer

Last Updates: 23/08/2020

Precision Digital PD2-6300-7H7

$1,529

Usually ships in 1 to 2 weeks

Part Number: PD2-6300-7H7  Categories: , Tags: , ,
  • Email Us: sales@celectric.com.my
  • WhatsApp Us: +60165519084
  • SKU: PD2-6300-7H7 
    Product Type: Large Display NEMA 4X Flow Rate/Totalizer 
    Input: Pulse 
    Output Options: 4 Relays & 4-20 mA Output 
    Power: 12-24 VDC/VAC 
    Approvals: UL/C-UL 
    Transmitter Power: 5 or 10 VDC @ 50 mA or 24 VDC @ 100 mA + 24 VDC @ 40 mA 
    Display Category: LED, Dual Line, Sunlight Readable, Large Display 
    Display: SunBright, 1.8″, Dual Line, 6 Digits, Red LED 
    Serial Comms: RS-485 Modbus 
    Warranty: 3 years 
    Product Family: PD2-6300 
    Product Category: Field Mounted Indicators 
    Product Application: Flow Rate Totalizer

    Wiring Diagram:

    What sets the Helios apart from other Large Display Meters is its dual line display with super bright LEDs that can be read even in bright sunlight and up to 100 feet away. Based on Precision Digital’s popular line of ProVu® digital panel meters, the Helios can satisfy a wide variety of level, flow, temperature, pressure, & weight applications. It is available with models that accept 4-20 mA, thermocouple, RTD, pulse, strain gauge, AC and DC volts and current, and even Modbus®.

    Go with the Helios PD2-6300 when you want to display both flow rate and total at the same time from a pulse output flowmeter. The PD2-6300 can display both flow rate and total in six full digits and can also be configured to display non-resettable grand total. The PD2-6300’s NEMA 4X, IP65 rated field mountable enclosure, super bright LEDs, and wide operating temperature range make it perfect for outdoor applications.

    Except where noted all specifications apply to operation at +25°C.

    General

    Display: Two lines with 1.8″ (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
    Display Intensity Eight user selectable intensity levels
    Display Update Rate: 5/second (200 ms)
    Overrange: Display flashes 999999
    Underrange: Display flashes -99999
    Display Assignment: Display lines 1 & 2 may be assigned to rate, total, grand total, alternate rate & total, max/min, units (lower display only), set points, Modbus input, & more.
    Programming Methods: Four programming buttons, digital inputs, PC and MeterView Pro software, or Modbus registers. 
    Noise Filter: Programmable from 2 to 199 (0 will disable filter)
    Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
    Recalibration: All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
    Max/Min Display: Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
    Password: Three programmable passwords restrict modification of programmed settings.
    Pass 1: Allows use of function keys and digital inputs
    Pass 2: Allows use of function keys, digital inputs and editing set/reset points
    Pass 3: Restricts all programming, function keys, and digital inputs.
    Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
    Isolated Transmitter Power Supply: Terminals P+ & P-: 24 VDC ± 10%. 12-24 VDC powered models selectable for 24, 10, or 5 VDC supply (internal P+/P- switch). 85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
    Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
    Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
    Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
    Isolation: 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply
    Overvoltage Category: Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
    Environmental: Operating temperature range: -40 to 150°F (-40 to 65°C); Storage temperature range: -40 to 185°F (-40 to 85°C); Relative humidity: 0 to 90% non-condensing
    Connections: Removable and integrated screw terminal blocks accept 12 to 22 AWG wire.
    Enclosure: UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts.
    Wall Mounting: Four (4) mounting holes provided for mounting meter to wall.
    Pipe Mounting: Optional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately. 
    See PD2-6300 manual for instructions.
    Tightening Torque: Removable Screw Terminals: 5 lb-in (0.56 Nm); 
    Digital I/O and RS485 Terminals: 2.2 lb-in (0.25 Nm)
    Overall Dimensions: 10.63″ x 12.59″ x 4.77″ (270 mm x 319.7 mm x 121.2 mm) (H x W x D)
    Weight: 6.10 lbs (2.76 kg)
    UL File Number: UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
    Warranty: 3 years parts & labor
    USB Connection: Compatibility: USB 2.0 Standard, Compliant
    Connector Type: Micro-B receptacle
    Cable: USB A Male to Micro-B Cable
    Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
    Power: USB Port

    Rate Input

    Inputs: Field selectable: Pulse or square wave 0-5 V, 0-12 V, or 0 24 V @ 30 kHz; TTL; open collector 4.7 kΩ pull-up to 5 V @ 30 kHz; NPN or PNP transistor, switch contact 4.7 kΩ pull-up to 5 V @ 40 Hz; Modbus PV (Slave)
    Low Voltage Mag Pickup (Isolated): Sensitivity: 40 mVp-p to 8Vp-p
    Minimum Input Frequency:0.001 Hz
    Minimum frequency is dependent on high gate setting.
    Maximum Input Frequency:30,000 Hz (10,000 for low voltage mag pickup)
    Input Impedance:Pulse input: Greater than 300 kΩ @ 1 kHz.
    Open collector/switch input: 4.7 kΩ pull-up to 5 V.
    Accuracy: ±0.03% of calibrated span ±1 count
    Temperature Drift: Rate display is not affected by changes in temperature.
    Multi-Point Linearization: 2 to 32 points
    Low-Flow Cutoff:0-999999 (0 disables cutoff function)
    Decimal Point: Up to five decimal places or none: d.ddddd, d.dddd, d.ddd, d.dd, d.d, or dddddd
    Calibration:May be calibrated using K-factor, internal calibration, or by applying an external calibration signal.
    K-Factor: Field programmable K-factor converts input pulses to rate in engineering units. May be programmed from 0.00001 to 999,999 pulses/unit.
    Calibration Range: Input 1 signal may be set anywhere in the range of the meter; input 2 signal may be set anywhere above or below input 1 setting. Minimum input span between any two inputs is 10 Hz.
    An error message will appear if the input 1 and input 2 signals are too close together.
    Filter: Programmable contact de-bounce filter: 40 to 999 Hz maximum input frequency allowed with low speed filter.
    Time Base: Second, minute, hour, or day
    Gate: Low gate: 0.1-99.9 seconds High gate: 2.0-999.9 seconds
    F4 Digital Input Contacts: 3.3 VDC on contact. Connect normally open contacts across F4 to COM.
    F4 Digital Input Logic Levels: Logic High: 3 to 5 VDC, Logic Low: 0 to 1.25 VDC

    Rate/Totalizer

    Display Assignment: The Upper and Lower displays may be assigned to rate, total, grand total, alternate rate/total, alternate rate/grand total, set points, alternate rate/units, alternate total/units, alternate grand total/units, display Hi, display Lo, display Hi/Lo, display modbus, display units (lower display) and display Off (lower display).
    Rate Display Indication: -99999 to 999999, lead zero blanking. “R” LED illuminates while displaying rate.
    Total Display & Total Overflow: 0 to 999,999; automatic lead zero blanking. “T” LED is illuminated while displaying total or grand total.
    Up to 999,999,999 with total-overflow feature. “oF” is displayed to the left of total overflow and ▲ LED is illuminated.
    Alternating Display:Either display may be programmed to alternate between rate and total or rate and grand total every 10 seconds.
    Total Decimal Point:Up to five decimal places or none: d.ddddd, d.dddd, d.ddd, d.dd, d.d, or dddddd
    Total decimal point is independent of rate decimal point.
    Totalizer: Calculates total based on rate and field programmable multiplier to display total in engineering units. Time base must be selected according to the time units in which the rate is displayed.
    Totalizer Rollover: Totalizer rolls over when display exceeds 999,999,999. Relay status reflects display.
    Total Overflow Override: Program total reset for automatic with 0.1 second delay and set point 1 for 999,999
    Totalizer Presets: Up to eight, user selectable under setup menu. Any set point can be assigned to total and may be programmed anywhere in the range of the meter for total alarm indication. 
    Programmable Delay On Release: 0.1 and 999.9 seconds; applied to the first relay assigned to total or grand total.
    If the meter is programmed to reset total to zero automatically when the preset is reached, then a delay will occur before the total is reset. 
    Total Reset:Via front panel button, external contact closure on digital inputs, automatically via user selectable preset value and time delay, or through serial communications.
    Total Reset Password: Total and grand total passwords may be entered to prevent resetting the total or grand total from the front panel.
    Non-Resettable Total: The grand total can be programmed as a non-resettable total by entering the password “050873”.
    CAUTION! Once the Grand Total has been programmed as “non-resettable” the feature cannot be disabled.

    Relays

    Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (≈ 50 W) @ 125/250 VAC for inductive loads
    Noise Suppression: Noise suppression is recommended for each relay contact switching inductive loads. See manual for details.
    Deadband: 0-100% of span, user programmable
    High Or Low Alarm: User may program any alarm for high or low trip point. Unused alarm LEDs and relays may be disabled (turn off).
    Relay Operation: Automatic (non-latching) and/or manual reset; Latching (requires manual acknowledge) with/without clear; Pump alternation control (2 to 4 relays); Sampling (based on time); Off (disable unused relays and enable Interlock feature); Manual on/off control mode
    Relay Reset: User selectable via front panel buttons or digital inputs

    1. Automatic reset only (non-latching), when the input passes the reset point.
    2. Automatic + manual reset at any time (non-latching)
    3. Manual reset only, at any time (latching)
    4. Manual reset only after alarm condition has cleared (latching)

    Note: Front panel button or digital input may be assigned to acknowledge relays programmed for manual reset.
    Time Delay: 0 to 999.9 seconds, on & off relay time delays; Programmable and independent for each relay
    Fail-Safe Operation: Programmable and independent for each relay. Note: Relay coil is energized in non-alarm condition. In case of power failure, relay will go to alarm state.
    Auto Initialization: When power is applied to the meter, relays will reflect the state of the input to the meter.

    Isolated 4-20 mA Transmitter Output

    Output Source: Process variable (PV), max, min, set points 1-4, Modbus input, or manual control mode
    Scaling Range: 1.000 to 23.000 mA for any display range
    Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output
    Analog Out Programming: 23.000 mA maximum for all parameters: Overrange, underrange, max, min, and break
    Accuracy: ± 0.1% of span ± 0.004 mA
    Temperature Drift: 0.4 µA/°C max from 0 to 65°C ambient, 0.8 µA/°C max from -40 to 0°C ambient
    Note: Analog output drift is separate from input drift.
    Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 10%. Isolated from the input at >500 V. May be used to power the 4-20 mA output or other devices. All models rated @ 40 mA max.
    External Loop Power Supply: 35 VDC maximum
    Output Loop Resistance:

    Power supplyMinimumMaximum
    24 VDC10 Ω700 Ω
    35 VDC (external)100 Ω1200 Ω

    RS485 Serial Communications Terminal

    Compatibility: EIA-485
    Connectors: Removable screw terminal connector
    Max Distance: 3,937′ (1,200 m) max
    Status Indication: Separate LEDs for Power (P), Transmit (TX), and Receive (RX)

    Modbus® RTU Serial Communications Protocol

    Slave: ID 1 – 247 (Meter address)
    Baud Rate: 300 – 19,200 bps
    Transmit Time Delay: Programmable between 0 and 199 ms
    Data: 8 bit (1 start bit, 1 or 2 stop bits)
    Parity: Even, Odd, or None with 1 or 2 stop bits
    Byte-To-Byte Timeout: 0.01 – 2.54 second
    Turn Around Delay: Less than 2 ms (fixed)
    Note: Refer to the Modbus Register Tables located at www.predig.com for details.

    Digital Input & Output Terminal

    Channels: 4 digital inputs & 4 digital outputs
    Digital Input Logic High: 3 to 5 VDC
    Digital Input Logic Low: 0 to 1.25 VDC
    Digital Output Logic High: 3.1 to 3.3 VDC
    Digital Output Logic Low: 0 to 0.4 VDC
    Source Current: 10 mA maximum output current
    Sink Current: 1.5 mA minimum input current
    +5 V Terminal: To be used as pull-up for digital inputs only. Connect normally open pushbuttons across +5 V & DI 1-4.
    WARNING! DO NOT use +5 V terminal to power external devices.

    Dimensions

     

    Helios Large Display Meter dimensions

     

    Dimensions

     

    Helios Large Display Meter dimensions

     


    Wall Mounting

    The meter can be mounted to any wall using the four provided mounting holes. Note that the bottom mounting holes are located underneath the front door panel. To mount the meter to a wall, follow these instructions.

    1. Prepare a section of wall approximately 11″ x 13″ (280 mm x 330 mm) for meter mounting by marking with a pencil the mounting holes (shown in the image to the right) on the wall.
    2. Using a drill bit slightly smaller than the girth of the mounting screws, pre-drill holes at the mounting locations previously marked.
    3. Insert mounting screws into the four mounting holes and screw them into the pre-drilled holes. Do not overtighten the mounting screws as it is possible that the enclosure could crack and become damaged.

     

    Helios Large Display Meter dimensionsMeter Mounting Holes

    Pipe Mounting

    The meter can also be mounted to a pipe using the optional pipe mounting kit (PDA6260). This kit includes two mounting plates, two U-bolts, and the necessary nuts and bolts. To mount the meter to a pipe using the pipe mounting kit accessory, follow these instructions.

    1. Secure the mounting plates to the top and bottom (for vertical pipes) or left and right (for horizontal pipes) of the reverse side of the meter enclosure using the provided fasteners. Do not overtightenthe fasteners as it could cause damage to the enclosure.
    2. Using the provided nuts and U-bolts, secure the mounting plates to the pipe enough torque such that the meter cannot be moved up or down (or side to side).

    Helios Large Display Meter dimensions

    Horizontal Pipe Mount Assembly

     

    Helios Large Display Meter dimensions
    Vertical Pipe Mount Assembly

    Applications

    Differential Pressure Flow

    The Helios PD2-6200 can display flow rate and total by extracting the square root from the 4-20 mA signal from a differential pressure transmitter. The user selectable low-flow cutoff feature gives a reading of zero when the flow rate drops below a user selectable value.

    • Display Flow Rate
    • User Selectable Low-Flow Cutoff
    • Only 2 Calibration Points Required

    Convert Pulse to 4-20 mA with PD2-6300

    The Helios PD2-6300 accepts the pulse output from a flowmeter and with the appropriate option installed can convert the pulse to a 4-20 mA signal. The 4-20 mA signal can be programmed to correspond to either the flow rate or the total flow.

    • Use K-Factor or Multi-Point Scaling
    • Helios Powers the Flowmeter
    • Display Flow Rate & Total

    Open Channel Flow

    The PD2-6200, in combination with an ultrasonic level transmitter, makes for an economical way to measure and display open channel flow rate and total in most weirs and flumes and take periodic samples. All the user needs to do is enter the exponent for the weir or flume into the PD2-6200 and the PD2-6200 automatically raises the input signal to that power. Sampling can be based on the total flow or the flow rate. For instance, to display open channel flow rate and total from a 3 inch Parshall flume and take a one pint sample every 100,000 gallons, the user would program the PD2-6200 as follows:

    FunctionDesireProgramming
    Open Channel Flow3″ Parshall flumeSet Programmable Exponent to 1.547
    Flow RateMillions of Gallons per Day (MGD)Set 4 mA = 0 & 20 mA = 3.508
    Time base = Day
    TotalMillions of GallonsSet Totalizer Conversion Factor = 1
    (password protect total reset)
    Non-Resettable Grand TotalProgram meter so grand total can never be resetSet non-resettable grand total password
    DisplayDisplay Flow Rate and Total at the same timeSet main display for Grand Total and secondary display to toggle between rate and total
    SamplingTake a 1 pint sample every 100,000 gallonsSet up relay for sampling and to trip every 0.1 million gallons. Set up sampling time such that 1 pint is sampled

    Total Relay Sampling Operation

    Connections Labeling

     

    The connectors’ label, affixed to the inside of the lower door panel, shows the location of all connectors available with requested configuration.

    Helios Large Display Meter Connections

     

    MeterView® Pro Software

    MeterView Pro VideoMeterView® Pro software is designed for use with ProVu, ProtEX-MAX, or Helios Series meters and allows users to remotely program, monitor, and datalog using a PC. Remote programming allows for all available meter settings to be programmed through an easy, user-friendly interface. The data acquisition feature allows the user to gather readings from a meter at user-selected intervals and generate charts using common tools like Microsoft® Excel. A linearization setup function is also included. With this utility the user can configure up to 32 linearization points and upload them to the meter. All configuration data can be saved to a file for future use.
    This software is accessible via the onboard USB connection on all Helios large display meters, ProVu panel meters, and ProVu-based ProtEX-MAX explosion-proof meters produced since 6 September 2016 (firmware version 4.0 or higher). In order for meters produced prior to 6 September 2016 (firmware version 3.1 or lower) to establish digital communications with a PC, a serial communications adapter is required. For an RS-232 connection, use a PDA1232 adapter.
    To determine the software version of a meter:

    1. Go to the Diagnostics menu () and press Enter button.
    2. Press Up arrow button and scroll to Information menu (Info).
    3. Press Enter to access the software number (), version (), and serial number () information. Write down the information as it is displayed. Continue pressing Enter until all the information is displayed.
    4. The meter returns to Run Mode after displaying all the settings.

     

    Monitor and Datalog

    Monitor and Datalog

    Setup

    Setup

    Programming

    Programming

    Relays

    Relays

     

    Wall Mounting

    The meter can be mounted to any wall using the four provided mounting holes. Note that the bottom mounting holes are located underneath the front door panel. To mount the meter to a wall, follow these instructions.

    1. Prepare a section of wall approximately 11″ x 13″ (280 mm x 330 mm) for meter mounting by marking with a pencil the mounting holes (shown in the image to the right) on the wall.
    2. Using a drill bit slightly smaller than the girth of the mounting screws, pre-drill holes at the mounting locations previously marked.
    3. Insert mounting screws into the four mounting holes and screw them into the pre-drilled holes. Do not overtighten the mounting screws as it is possible that the enclosure could crack and become damaged.

     

    Helios Large Display Meter dimensionsMeter Mounting Holes

    Pipe Mounting

    The meter can also be mounted to a pipe using the optional pipe mounting kit (PDA6260). This kit includes two mounting plates, two U-bolts, and the necessary nuts and bolts. To mount the meter to a pipe using the pipe mounting kit accessory, follow these instructions.

    1. Secure the mounting plates to the top and bottom (for vertical pipes) or left and right (for horizontal pipes) of the reverse side of the meter enclosure using the provided fasteners. Do not overtightenthe fasteners as it could cause damage to the enclosure.
    2. Using the provided nuts and U-bolts, secure the mounting plates to the pipe enough torque such that the meter cannot be moved up or down (or side to side).

    Helios Large Display Meter dimensions

    Horizontal Pipe Mount Assembly

     

    Helios Large Display Meter dimensions
    Vertical Pipe Mount Assembly

    Applications

    Differential Pressure Flow

    The Helios PD2-6200 can display flow rate and total by extracting the square root from the 4-20 mA signal from a differential pressure transmitter. The user selectable low-flow cutoff feature gives a reading of zero when the flow rate drops below a user selectable value.

    • Display Flow Rate
    • User Selectable Low-Flow Cutoff
    • Only 2 Calibration Points Required

    Convert Pulse to 4-20 mA with PD2-6300

    The Helios PD2-6300 accepts the pulse output from a flowmeter and with the appropriate option installed can convert the pulse to a 4-20 mA signal. The 4-20 mA signal can be programmed to correspond to either the flow rate or the total flow.

    • Use K-Factor or Multi-Point Scaling
    • Helios Powers the Flowmeter
    • Display Flow Rate & Total

    Open Channel Flow

    The PD2-6200, in combination with an ultrasonic level transmitter, makes for an economical way to measure and display open channel flow rate and total in most weirs and flumes and take periodic samples. All the user needs to do is enter the exponent for the weir or flume into the PD2-6200 and the PD2-6200 automatically raises the input signal to that power. Sampling can be based on the total flow or the flow rate. For instance, to display open channel flow rate and total from a 3 inch Parshall flume and take a one pint sample every 100,000 gallons, the user would program the PD2-6200 as follows:

    FunctionDesireProgramming
    Open Channel Flow3″ Parshall flumeSet Programmable Exponent to 1.547
    Flow RateMillions of Gallons per Day (MGD)Set 4 mA = 0 & 20 mA = 3.508
    Time base = Day
    TotalMillions of GallonsSet Totalizer Conversion Factor = 1
    (password protect total reset)
    Non-Resettable Grand TotalProgram meter so grand total can never be resetSet non-resettable grand total password
    DisplayDisplay Flow Rate and Total at the same timeSet main display for Grand Total and secondary display to toggle between rate and total
    SamplingTake a 1 pint sample every 100,000 gallonsSet up relay for sampling and to trip every 0.1 million gallons. Set up sampling time such that 1 pint is sampled

    Total Relay Sampling Operation

    Connections Labeling

     

    The connectors’ label, affixed to the inside of the lower door panel, shows the location of all connectors available with requested configuration.

    Helios Large Display Meter Connections

     

    MeterView® Pro Software

    MeterView Pro VideoMeterView® Pro software is designed for use with ProVu, ProtEX-MAX, or Helios Series meters and allows users to remotely program, monitor, and datalog using a PC. Remote programming allows for all available meter settings to be programmed through an easy, user-friendly interface. The data acquisition feature allows the user to gather readings from a meter at user-selected intervals and generate charts using common tools like Microsoft® Excel. A linearization setup function is also included. With this utility the user can configure up to 32 linearization points and upload them to the meter. All configuration data can be saved to a file for future use.
    This software is accessible via the onboard USB connection on all Helios large display meters, ProVu panel meters, and ProVu-based ProtEX-MAX explosion-proof meters produced since 6 September 2016 (firmware version 4.0 or higher). In order for meters produced prior to 6 September 2016 (firmware version 3.1 or lower) to establish digital communications with a PC, a serial communications adapter is required. For an RS-232 connection, use a PDA1232 adapter.
    To determine the software version of a meter:

    1. Go to the Diagnostics menu () and press Enter button.
    2. Press Up arrow button and scroll to Information menu (Info).
    3. Press Enter to access the software number (), version (), and serial number () information. Write down the information as it is displayed. Continue pressing Enter until all the information is displayed.
    4. The meter returns to Run Mode after displaying all the settings.

     

    Monitor and Datalog

    Monitor and Datalog

    Setup

    Setup

    Programming

    Programming

    Relays

    Relays

    Data Sheet: LDS2-6200 Datasheets

    Instruction Manual:  LIM2-6300_0 Instruction Manuals