The Endress & Hauser Prosonic Flow P clamp-on sensor was specially designed for the process industry. Combined with the Prosonic Flow 93 transmitter with touch control, four-line display and extended functionality Prosonic Flow 93P offers high accuracy in standard applications.
● Automatic frequency scan for maximum measuring performance
● Increased safety for chemical and petrochemical industry – international hazardous area approvals
● No additional leakage paths – external measurement from outside the pipe
● Process transparency – diagnostic capability
● Highest performance – extended functionality and diagnostics
● Flexible data transfer options – numerous communication types
● Automatic recovery of data for servicing
● The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
● Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids and alkalis.
Device properties
● Medium temperature: –40 to 170 °C (–40 to 338 °F)
● Wide nominal diameter range: DN 15 to 4000 (1/2 to 160″)
● Process piping unaffected by meter installation
● Aluminium transmitter housing
● 4‐line backlit display with touch control
● HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
Product headline
The flowmeter for hazardous area installations with a wide range of analog and digital outputs. Automatic frequency scan for maximum measuring performance. Ideal clamp-on device for applications with chemicals, solvents, liquid hydrocarbons, acids and alkalis.
Sensor features
Increased safety for chemical and petrochemical industry – international hazardous area approvals. No additional leakage paths – external measurement from outside the pipe. Process transparency – diagnostic capability. Medium temperature: –40 to 170 °C (–40 to 338 °F). Wide nominal diameter range: DN 15 to 4000 (½ to 160″).
Transmitter features
Highest performance – extended functionality and diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. Aluminium transmitter housing. 4‐line backlit display with touch control.
Nominal diameter range
Single channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160″)
Dual channel, 1 or 2 paths : DN15 to 4000 (1/2 to 160″)Wetted materials
Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304Measured variables
Volume flow channel 1&2, average volume flow, volume flow difference, sound velocity, flow velocity, totalizer
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to DN200
±2% o.r. above DN200Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
Max. process pressure
N/A
Medium temperature range
DN15 to 65
-40 to +100°C (-40 +212 °F)
-40 to +150°C (-40 +302 °F) optionDN50 to 4000
-40 to +80°C (-40 +276 °F)
-40 to +170°C (-40 +338 °F) optionAmbient temperature range
-20 to +60 °C (-4 to +140 °F)
-40 to +60 °C (-40 to +140 °F) optionalSensor housing material
N/A
Transmitter housing material
Wall-mounted housing: powder-coated die-cast aluminum
Degree of protection
IP67, type 4X for transmitter
IP68 type 6P for sensors. Transmitter: IP67, type 4X enclosureDisplay/Operation
4 lines backlit display with three optical keys
Outputs
1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)Inputs
N/A
Digital communication
HART
PROFIBUS PA
Profibus DP
FOUNDATION FieldbusPower supply
85 to 260 V AC
20 to 55 V AC
16 to 62V DCHazardous area approvals
ATEX, FM/CSA, NEPSI, TIIS
Other approvals and certificates
Flowmeter verification for DN15, 25, 40, 50 & 100 only
Marine certificate
EAC markingProduct safety
EAC marking
Metrological approvals and certificates
Flowmeter verification for DN15, 25, 40, 50 & 100 only
Marine approvals and certificates
Marine certificate