Promass S is at the forefront in hygienic design and dedicated to applications in the food and beverage industry requiring optimal cleanability. The self‐drainable single-tube system ensures careful treatment of fluids. With its compact transmitter Promass S 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures process safety at all times.

● Increased process safety – easily cleanable and fully self-drainable tube design
● Fewer process measuring points – multivariable measurement (flow, density, temperature)
● Space-saving installation – no in/outlet run needs
● Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
● Reduced complexity and variety – freely configurable I/O functionality
● Integrated verification – Heartbeat Technology

 

● Measuring principle operates independently of physical fluid properties such as viscosity or density
● Dedicated to applications requiring optimal cleanability under hygienic conditions.

Device properties
● Large range of hygienic process connections
● 3-A and EHEDG conform
● Fast recovery from CIP/SIP
● Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os
● Backlit display with touch control and WLAN access
● Remote display available

 

 

  • Measuring principle

    Coriolis

  • Product headline

    Easy-to-clean flowmeter with self-drainable single-tube system and a compact, easily accessible transmitter. Dedicated to applications requiring optimal cleanability under hygienic conditions.

  • Sensor features

    Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform.

  • Transmitter features

    Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access.

  • Nominal diameter range

    DN 8 to 50 (⅜ to 2″)

  • Wetted materials

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

  • Measured variables

    Mass flow (liquid): ±0.10 % 
    Volume flow (liquid): ±0.10 % 
    Mass flow (gas): ±0.50 % 
    Density (liquid): ±0.0005 g/cm³

  • Max. measurement error

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Measuring range

    PN 40, Class 150, 20K

  • Max. process pressure

    –50 to +150 °C (–58 to +302 °F)

  • Medium temperature range

    Standard: –40 to +60 °C (–40 to +140 °F) 
    Option: –50 to +60 °C (–58 to +140 °F)

  • Ambient temperature range

    1.4301 (304), corrosion resistant

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    AlSi10Mg, coated; stainless steel for hygenic transmitter design

  • Degree of protection

    IP66/67, type 4X enclosure 
    IP69

  • Display/Operation

    4-line backlit display with touch + control (operation from outside) 
    Configuration via local display and operating tools possible 
    Remote display available

  • Outputs

    3 outputs: 
    4-20 mA HART (active/passive) 
    4-20 mA WirelessHART 
    4-20 mA (active/passive) 
    Pulse/frequency/switch output (active/passive) 
    Double pulse output (active/passive) 
    Relay output

  • Inputs

    Status input 
    4-20 mA input

  • Digital communication

    HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

  • Power supply

    DC 24 V 
    AC 100 to 230 V 
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC

  • Product safety

    CE, C-tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
    Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)”

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, EHEDG, cGMP

Datasheet: Proline Promass S 300 Technical Information