Promass P offers the enhanced performance of a bent tube meter and the drainability of a straight tube meter without any compromise, between accuracy and drainability. Combined with the proven Promass 80 transmitter with push buttons, Promass 80P offers a cost effective solution for applications in sterile environments in the life sciences industry.
● Highest process quality – fully compliant to industry requirements
● Fewer process measuring points – multivariable measurement (flow, density, temperature)
● Space-saving installation – no in/outlet run needs
● Cost-effective – dedicated design for standard applications
● Safe operation – display provides easy readable process information
● Fully industry compliant – IEC/EN/NAMUR
● Measuring principle operates independently of physical fluid properties such as viscosity or density
● Dedicated for applications under sterile conditions in the life sciences industry.
Device properties
● Straight, easy cleanable single-tube system
●Electropolished measuring tube in 1.4435 (316L)
● Fast recovery from CIP/SIP
● 2-line backlit display with push buttons
● Device in compact or remote version
● HART, PROFIBUS PA
Product headline
The specialist for life sciences with a compact or remote transmitter. Dedicated for applications under sterile conditions in the life sciences industry.
Sensor features
Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. ASME BPE, 3-A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L).
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range
DN 8 to 50 (⅜ to 2″)
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error
Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 63, Class 300, 40K
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), castDegree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possibleOutputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)Inputs
Status input
Digital communication
HART
PROFIBUS PAPower supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI, TIIS
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3-A, FDA, ASME BPE, ISPEProduct safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, FDA, ASME BPE, ISPE