Promag L is the versatile standard sensor for the water and wastewater industry with a lap-joint flange concept for flexible installation independent of the orientation of the pipe flange pitch diameter. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10L offers accurate measurement of liquids for a wide range of applications. It will be the preferred solution for customers aiming for minimized cost of ownership.
● Reduced installation costs – flexible mounting by one-of-a-kind lap-joint flange concept (DN < 350/14″)
● Energy-saving flow measurement – no pressure loss due to cross-section constriction
● Maintenance-free – no moving parts
● Cost-effective – designed for easy applications and direct integration
● Safe operation – display provides easily readable process information
● Fully industry compliant – IEC/EN/NAMUR
● The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
● Fully suitable for standard applications in the water and wastewater industry.
Device properties
● Up to 30 % less sensor weight
● Nominal diameter: DN 25 to 2400 (1 to 90″)
● Maximum reduced installation length to DVGW/ISO
● 2-line display with push buttons
● Device as compact or remote version
● HART
Product headline
The flowmeter with a weight-optimized sensor and high cost-effectiveness. Fully suitable for standard applications in the water and wastewater industry.
Sensor features
Reduced installation costs – flexible mounting by one‐of‐a‐kind lap‐joint flange concept (DN <350/14″). Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Up to 30 % less sensor weight. Nominal diameter: DN 25 to 2400 (1 to 90″).
Transmitter features
Cost-effective – designed for easy applications and direct integration. Safe operation – display provides easily readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line display with push buttons. Device as compact or remote version.
Nominal diameter range
Lap joint flange; lap joint flange, stamped plate: DN 25 to 300 (1 to 12″)
Fixed flange: DN 350 to 2400 (14 to 90″)Wetted materials
Liner: PTFE; Polyurethane; Hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)Measured variables
Volume flow
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
Measuring range
9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)
Max. process pressure
PN 16, Class 150
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)Sensor housing material
DN 25 to 300 (1 to 12″): AlSi10Mg, coated
DN 350 to 2400 (14 to 90″): Carbon steel with protective varnish
Sensor connection housing: AlSi10Mg, coatedTransmitter housing material
Powder‐coated die‐cast aluminum
Degree of protection
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP67, type 4X enclosureDisplay/Operation
2-line display with push buttons
Configuration via local display and operating tools possibleOutputs
4‐20 mA HART (active)
Pulse/switch output (passive)
Inputs
None
Digital communication
HART
Power supply
DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)
Hazardous area approvals
cCSAus
Product safety
CE, C-tick
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Hygienic approvals and certificates
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920