Micropilot NMR84 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The NMR84 free space radar with drip-off planar antenna is specifically suited for stilling well applications. The superior drip-off antenna design with proven track record eliminates problems caused by condensation.
- Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety
- Maximum reliability through accuracy up to ±0.5mm (±0.02″)
- Developed according to international metrology recommendations such as OIML R85 and API MPMS
- Local and country-specific certifications like NMi or PTB for custody transfer applications
- Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols
- Unique drip-off antenna design eliminates measurement error due to condensation build-up
With planar antenna particularly suited for stilling well applications.
- Process connections: Flanges
- Temperature: -40 to +150°C (-40 to +302°F)
- Pressure: Vacuum to +25bar (Vacuum to +362psi)
- Maximum measuring range: 40m (131ft)
- Accuracy: ±0.5mm (±0.02″)
- Transmitting frequency: 6GHz
- International explosion protection and custody transfer certificates, overfill prevention WHG, SIL
Characteristic / Application
Planar antenna, 6GHz: High precision measurement for for storage tanks up to 30 m (98ft)
Specialities
Custody transfer level measurement
Supply / Communication
85-264VAC
Accuracy
up to 0.5 mm
Ambient temperature
Standard:
-40°C…60°C
(-40°F…140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F…131°F)
Process temperature
-40°C…150°C
(-40°F…302°F)
Process pressure absolute / max. overpressure limit
Vacuum … 25 bar abs
Main wetted parts
316L, PTFE
Process connection
Flange:
DN100/4″…DN300/12″
UNI-Flange:
DN150/6″…DN300/12″
Max. measurement distance
40 m (131 ft)
For calibration to regulatory standards:
30 m (98 ft)
Communication
Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active)
Certificates / Approvals
ATEX, FM, IEC Ex, EAC
Design approvals
EN 10204-3.1
NACE MR0175, MR0103
AD2000
Metrological approvals and certificates
OIML, NMi, PTB
Options
Redundant fieldbus
Alu-coated or 316L housing
Weather protection cover
Application limits
Maximum measuring range is
dependent on the tank form and/
or application
Strong condensate or build-up
formation
Datasheet: Micropilot NMR84 Technical Information