Last Updates: 16/08/2020

E&H Prosonic FMU44 Ultrasonic measurement Time-of-Flight

Part Number: FMU44 Categories: ,
  • Email Us: sales@celectric.com.my
  • WhatsApp Us: +60165519084
  • The Prosonic FMU44 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

    • Reliable non-contact measurement
    • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
    • Envelope curves on the on-site display for simple diagnosis
    • Hermetically sealed and potted sensor
    • Chemically resistant sensor out of PVDF
    • Calibration without filling or discharging
    • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

    Two-wire or four wire instrument for continuous non-contact level and flow measurement.

    • Process connection: Flange
    • Temperature: -40 to +80°C (-40 to +176°F)
    • Pressure: +0.7 to +2.5bar (+10 to +36psi)
    • Maximum measuring distance: Liquids 20m (66ft), Solids 10m (33ft)
    • Blocking distance: Liquids and Solids 0.5m (1.9ft)
    • International explosion protection certificates
    • Measuring principle

      Ultrasonic

    • Characteristic / Application

      Compact ultrasonic transmitter

    • Supply / Communication

      2/4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

    • Accuracy

      +/- 4mm or +/- 0,2 % of set measuring range

    • Ambient temperature

      -40 °C … 80 °C
      (-40 °F … 176 °F)

    • Process temperature

      -40 °C … 80 °C
      (-40 °F … 176 °F)

    • Process pressure absolute / max. overpressure limit

      0,7 bar … 2,5 bar abs 
      (10 psi … 36 psi)

    • Main wetted parts

      PVDF

    • Process connection

      Flange
      DN100, ASME 4″, JIS 10K 100
      DN150, ASME 6″, JIS 10K 150
      DN200, ASME 8″, JIS 10K 200
      Mounting bracket

    • Blocking distance

      0.5 m (1.9 ft)

    • Application
       
    • Max. measurement distance

      20 m (66 ft)

    • Communication

      4 … 20 mA HART
      PROFIBUS PA
      FOUNDATION Fieldbus

    • Certificates / Approvals

      ATEX, FM, CSA, INMETRO, NEPSI

    • Application limits

      Fast filling and discharging rate:

      FMU90 + FDU9x

      Level limit detection:

      FMU90 + FDU9x

    Datasheet: Prosonic M FMU40,41,42,43,44 Technical Information

    Scroll to Top
    ×