Last Updated: 22/07/2019

E&H Microwave barrier receiver Soliwave FDR56

Request a Quote
close-link

Part Number: FDR56 Category:
  • Free Shipping
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email sales@celectric.com.my

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
  • Free Technical Support
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
  • The Soliwave FDR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FQR56 emitter.

    • Highly reliable measurement due to flush-mounted installation and possible non-contact installation as well as indication of the signal strength on the receiver
    • Mechanical robust solution ensures cost savings over the whole life cycle of the product: No wear and tear, process-wetted ceramic sensor diaphragm (optional), long serviceable life, maintenance free
    • Electronics housing can be rotated by 360°, allowing adjustment into optimum position after installation
    • Direct connection of the supply voltage (emitter and receiver separately or together)
    • Mechanically compatible to FQR50/FDR50 microwave barrier, existing process connections can continue to be used; likewise, accessories such as adapter flanges, installation brackets and sight glasses can continue to be used

    Typical bulk solids are: Wood chips, wood dust or flour; plaster, cement, ash; paper or cardboard shred, gravel, sand, dried powders in general, bags and boxes.

    • Process connections: Threads
    • Ambient temperature: -40 to +70°C (-40 to +158°F)
    • Measuring range: Max. 100m (328ft)
    • International explosion protection certificates
    • Measuring principle

      Microwave barrier

    • Characteristic / Application

      Transceiver

      Non-contact point level detection and flow monitoring

      Detecting, counting and positioning of objects

      Monitoring of material transfer points

      Detection and analysis of deposits and contamination

      Installation:

      Non-contact installation (transmission window) or front-flush installation (contact)

    • Specialities

      Measuement range: max. 100 m

    • Supply / Communication

      85 … 253 VAC

      20 … 60 VDC/ 20 … 30 VAC

    • Ambient temperature

      -40 °C…+70 °C

      (-40°F…+158°F)

    • Process temperature

      Non-contact installation: any

      Within installation:

      -40 °C…+70 °C (-40 °F…+158 °F)

      With HT-Adapter:

      up to +450 °C (+842 °F)

    • Process pressure absolute / max. overpressure limit

      Non-contact installation: any

      Within installation:

      0.5 bar … 6.8 bar (7.2 psi … 99 psi) abs.

      With HD-Adapter:

      up to +21 bar (+305 psi) abs.

    • Min. density of medium

      Solid weight: > 10 g/l

    • Main wetted parts

      Non-contact installation:
      no wetted parts

      Within installation:

      316Ti or Aluminium;

      PTFE or Ceramic

    • Process connection

      1-1/2″ R, 1-1/2″ G, 1-1/2″ NPT

    • Process connection hygienic

      Non-contact installation

    • Communication

      Relays SPDT

      Solid-State-Relaiy

      4 … 20 mA

    • Certificates / Approvals

      ATEX, CSA C/US, IEC Ex

    • Design approvals

      EN10204-3.1

    • Options

      Sight glass

      High temperature adapter

      High pressure adapter

      Installation bracket

      FAR50, FAR51, FAR52, FAR53, FAR54, FAR55

    • Components

      Transmitter: FQR56

    • Application limits

      Solid weight: < 10 g/l

    Datasheet: Accessory FAR52 Technical Information

    Accessory FAR50 Technical Information

    Accessory FAR54 Technical Information

    Microwave barrier Technical Information

    Accessory FAR51 Technical Information

    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm

    Setup, Configuration and Technical Support of our Products are FREE.

    We help to check your faulty Instruments too, fill in the form here

    Free phone and email tech support continues as long as you own the product. Click here for contact information.

    close-link
    celectric logo

    Questions? Call +604-502 1894 Mon-Fri 8:30am to 5:30pm or Email sales@celectric.com.my

    FREE Domestic AND SEA Shipping!

    Most orders RM500/USD120 or more ship SEA for FREE!

    • Delivery within the Southeast Asia only.
    • Hazardous items excluded.
    • Extremely heavy or bulky items excluded.
    • Distributors, Resellers and OEMs excluded.
    • Contact us for shipping charge for orders < RM500/USD120
    close-link
    close-link

    Product of the week

    Electromagnetic Flow Meter
    Wafer Connection Electromagnetic Flow Meter in-stock now, and deliver immediately.
    Free delivery within Malaysia.
    Buy Here!
    close-link
    Scroll to Top
    ×