Last Updates: 16/08/2020

E&H Micropilot FMR532 Radar measurement

Part Number: FMR532 Categories: ,
  • Email Us: sales@celectric.com.my
  • WhatsApp Us: +60165519084
  • The Micropilot FMR532 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The FMR532 free space radar with planar antenna is specifically suited for stilling well applications. Micropilot FMR532 offers cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.

    • 0.8mm accuracy (2σ value)
    • National approvals (NMi, PTB) for custody transfer
    • Applicable as stand-alone system or integrated into tank gauging systems via the Tank Side Monitor NRF590
    • Easy on-site operation via menu-driven alphanumeric display
    • Easy commissioning, documentation and diagnostics via FDT/DTM technology (FieldCare)
    • Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply
    • Unique drip-off antenna design eliminates measurement error due to condensation build-up

    With planar antenna particularly suited for stilling well applications with ranges up to 38m (124ft).

    • Process connection: Flange
    • Temperature: -40 to +150°C (-40 to +302°F)
    • Pressure: Vacuum to +25bar (Vacuum to +362psi)
    • Maximum measuring range: 38m (124ft)
    • Accuracy: Better than ±1mm
    • C-band: 6GHz
    • International explosion protection and custody transfer certificates, overfill prevention WHG, SIL, marine approval
    • Measuring principle

      Level radar

    • Characteristic / Application

      Ideal for high precision measurements in stilling well

    • Supply / Communication

      4-wire (HART)

    • Frequency

      C-band (~6 GHz)

    • Accuracy

      +/- 1 mm, custody transfer

    • Ambient temperature

      Standard:
      -40 °C … 80 °C
      (-40 °F … 176 °F)
      For calibration to regulatory standards:
      -25 °C … 60 °C
      (-13 °F … 131 °F)

    • Process temperature

      -40 °C … 150 °C
      (-40 °F … 302 °F)

    • Process pressure absolute / max. overpressure limit

      Vacuum … 25 bar 
      (Vaccum … 362 psi)

    • Main wetted parts

      316L + PTFE

    • Process connection

      DN150 … DN300 / 6″ … 12″

    • Application
       
    • Max. measurement distance

      38 m (124ft)

    • https://i2.wp.com/portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_Mediengruppe_en.jpg?w=1200&ssl=1 https://i1.wp.com/portal.endress.com/picpool/sft/prodcont/technicalinfo/Radar_not_selected_FMR532.jpg?w=1200&ssl=1
    • Communication

      4 … 20 mA

    • Certificates / Approvals

      ATEX, FM, CSA, IEC Ex, NEPSI

    • Safety approvals

      Overfill prevention WHG

    • Design approvals

      EN 10204-3.1

      NACE MR0175, MR0103

    • Marine approval

      GL/ ABS

    • Application limits

      Maximum measuring range is dependent on the tank form and/or application

      Free space and many baffles