fbpx
Last Updates: 21/04/2020

E&H Magphant Electromagnetic flowmeter

Part Number: Magphant Categories: ,

Email Us: sales@celectric.com.my
WhatsApp Us: +60165519084

The cost-effective, compact limit switch Magphant is an ideal flowmeter for water applications in Utilities. Its reliable measurement with high repeatability allows for univesal and easy use and supports safe process- and plant operation.

● High plant availability – reliable flow information
● Energy-saving flow measurement – no pressure loss due to cross-section constriction
● Maintenance-free – no moving parts
● Process safety – device self-monitoring and reliable monitoring even with empty piping
● Product safety – integrated testing to check correct functioning of the electronics
● Easy operation – potentiometer setting of full-scale value

 

● The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
● Universally usable for all water applications in Utilities.

Device properties
● Compact, space-saving design
● Nominal diameter: DN 15 to 2000 (1/2 to 80″)
● Applicable for steel or plastic pipes
● Switch point setting via rotary switch
● Current output and relay output
● ATEX, FM, CSA

 

 

 

  • Measuring principle

    Electromagnetic

  • Product headline

    Cost-effective limit switch for reliable and repeatable flow monitoring. Universally usable for all water applications in Utilities.

  • Sensor features

    High plant availability – reliable flow information. Energy-saving flow measurement – no pressure loss due to cross-section constriction. Maintenance-free – no moving parts. Compact, space-saving design. Nominal diameter: DN 15 to 2000 (½ to 80″).

  • Transmitter features

    Process safety – device self-monitoring and reliable monitoring even with empty piping. Product safety – integrated testing to check correct functioning of the electronics. Easy operation – potentiometer setting of full-scale value. Switch point setting via rotary switch. Current output and relay output.

  • Nominal diameter range

    DN15 to DN2000
    1/2″ to 80″

  • Wetted materials

    1.4435/316L

  • Measured variables

    Volume flow

  • Max. measurement error

    2%

  • Measuring range

    0 to 56’550 m3/h

  • Max. process pressure

    0 to 16 bar abs

  • Medium temperature range

    -20 to +120°C
    (-4 to +248°F)

  • Ambient temperature range

    -20…60 °C (-4 to 140°F)

  • Sensor housing material

    Die-cast aluminium, epoxy powder coated

  • Degree of protection

    IP 66 / NEMA 4X / Type 4X

  • Display/Operation

    Test function

  • Outputs

    4 to 20 mA
    Relay

  • Inputs

    None

  • Power supply

    24 V DC (20…30 V DC)

  • Hazardous area approvals

    FM
    CSA

  • Product safety

    CE, EAC

Datasheet: 

 