fbpx
Last Updates: 16/08/2020

E&H Liquiphant FTL51C Vibronic Point level detection

Part Number: FTL51C Categories: ,

Email Us: sales@celectric.com.my
WhatsApp Us: +60165519084

Liquiphant FTL51C is a point level switch with extension tube and highly corrosion resistant coating. For use in hazardous areas with all international certificates. Useable in all industries. FTL51 offers functional safety SIL2/SIL3. With the second line of defense highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.

  • Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with IEC 61508/IEC 61511-1
  • Different plastic coating (PFA) and enamel coating for applications with aggressive medias
  • International explosion protection certificates and overfill prevention certificate (WHG)
  • No calibration required, easy to start up
  • No mechanically moving parts: no maintenance, no wear, long operating life.Monitoring of fork for damage: guaranteed function
  • Second line of defense to protect the environmental
  • Variety of standardized process connections for all applications

Point level switch for all liquids with highly corrosion-resistant coating.

  • Process connections: Flanges and hygienic process connection (FDA conform with PFA)
  • Temperature: -50 to +150°C (-58 to +302°F)
  • Pressure: -1 to +40bar (-14.5 to +580psi)
  • Sensor material: ECTFE, PFA (Edlon, Rubyred, conductive), Enamel
  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    High protection against aggressive media by using antistatic coating
    Modular housing concept
    wide range of process connections
    Analogue and bus interfaces
    Extensive certificate range (e.g.Ex,WHG)

    pipe extension up to 3m (6m option)

  • Specialities

    Foamdetection
    Detekt a densitychange
    second line of defense

  • Supply / Communication

    PROFIBUS PA
    19…253V AC, 2-wire
    10…55V DC-PNP, 3-wire
    DPDT, 19…253V AC, 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM, 2-wire
    NAMUR with testbutton

  • Ambient temperature

    -50 °C…+70 °C
    (-58 °C…+158 °F)

  • Process temperature

    -50 °C…+150 °C
    (-58 °F…+302 °F)
    up to 230 °C / 450°F on request

  • Process pressure absolute / max. overpressure limit

    Vacuum…40 bar
    (Vacuum…580 psi)

  • Min. density of medium

    0.5g/cm³ (0.4g/cm³ optional)

  • Main wetted parts

    ECTFE
    PFA (Edlon)
    PFA (Rubyred)
    PFA (conductive)
    Enamel

  • Process connection

    Flange:

    DN25…DN100,

    ASME 1″…3″,

    JIS RF10 K 50

  • Process connection hygienic

    FDA conform with PFA (Edlon)

  • Sensor length

    ECTFE, PFA 130mm, 148mm…3000mm
    (ECTFE, PFA 5.12″, 5.83″…118″)
    Enamel 130mm, 148mm…1200mm
    (Enmal 5.12″, 5.83″…47.24″)

  • Communication

    PROFIBUS PA
    19…253V AC
    10…55V DC-PNP
    19…253V AC bzw 10…55V DC
    8/16mA, 11…36V DC
    NAMUR
    PFM

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Safety approvals

    Overfill prevention WHG

    SIL2/ SIL3

  • Design approvals

    EN 10204-3.1

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Heavy duty stainless steel housing mainly for the oil and gas industry

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

Datasheet: Technical Information Liquiphant M Density and Density Computer FML621

Liquiphant M FTL51C Technical Information

Scroll to Top
×